CISA issued thirteen Industrial Control Systems (ICS) advisories, highlighting current security issues and vulnerabilities in various systems.
These advisories are crucial for maintaining the security and integrity of industrial operations. The affected products primarily include several Siemens systems, along with a Sungrow and a Philips product.
Introduction to the Advisories
CISA emphasizes the importance of reviewing these advisories for technical details and mitigation strategies.
The advisories cover various vulnerabilities that can potentially lead to significant disruptions or unauthorized access if not addressed.
1.Siemens Teamcenter Visualization and Tecnomatrix Plant Simulation
- Alert Code: ICSA-25-072-01
- CVEs: CVE-2025-23396, CVE-2025-23397, CVE-2025-23398, CVE-2025-23399, CVE-2025-23400, CVE-2025-23401, CVE-2025-23402, CVE-2025-27438
- Vulnerabilities: Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Read, Use After Free
- Impact: These vulnerabilities could cause application crashes or lead to arbitrary code execution due to memory corruption.
2.Siemens SINEMA Remote Connect Server
- Alert Code: ICSA-25-072-02
- CVEs: CVE-2024-5594, CVE-2024-28882
- Vulnerabilities: Improper Output Neutralization for Logs, Missing Release of Resource after Effective Lifetime
- Impact: Exploitation could lead to high CPU load or extended session validity.
3.Siemens SIMATIC S7-1500 TM MFP
- Alert Code: ICSA-25-072-03
- CVEs: CVE-2024-41046, CVE-2024-41049, CVE-2024-41055, CVE-2024-42154, CVE-2024-42161
- Vulnerabilities: Double Free, Use After Free, NULL Pointer Dereference, Buffer Access with Incorrect Length Value, Use of Uninitialized Variable
- Impact: Successful exploitation allows for arbitrary code execution, denial-of-service conditions, or unauthorized access.
4.Siemens SiPass integrated AC5102/ACC-G2 and ACC-AP
- Alert Code: ICSA-25-072-04
- CVEs: CVE-2024-52285, CVE-2025-27493, CVE-2025-27494
- Vulnerabilities: Missing Authentication for Critical Function, Improper Input Validation
- Impact: An attacker could execute commands with root privileges and access sensitive data.
5.Siemens SINAMICS S200
- Alert Code: ICSA-25-072-05
- CVE: CVE-2024-56336
- Vulnerability: Improper Authentication
- Impact: Exploitation enables attackers to download malicious firmware.
6.Siemens SCALANCE LPE9403
- Alert Code: ICSA-25-072-06
- CVEs: CVE-2025-27392, CVE-2025-27393, CVE-2025-27394, CVE-2025-27395, CVE-2025-27396, CVE-2025-27397, CVE-2025-27398
- Vulnerabilities: OS Command Injection, Path Traversal, Improper Check for Dropped Privileges
- Impact: Successful exploitation allows arbitrary code execution, file access, or privilege escalation.
7.Siemens SCALANCE M-800 and SC-600 Families
- Alert Code: ICSA-25-072-07
- CVE: CVE-2025-23384
- Vulnerability: Partial String Comparison
- Impact: An attacker could obtain partial invalid usernames accepted by the server.
8.Siemens Tecnomatix Plant Simulation
- Alert Code: ICSA-25-072-08
- CVEs: CVE-2025-25266, CVE-2025-25267
- Vulnerabilities: Files or Directories Accessible to External Parties
- Impact: Unauthorized attackers could read or delete arbitrary files.
9.Siemens OPC UA
- Alert Code: ICSA-25-072-09
- CVEs: CVE-2024-42512, CVE-2024-42513
- Vulnerabilities: Observable Timing Discrepancy, Authentication Bypass by Primary Weakness
- Impact: An attacker could bypass application authentication and access managed data.
10. Siemens SINEMA Remote Connect Client
- Alert Code: ICSA-25-072-10
- CVEs: CVE-2024-1305, CVE-2024-4877, CVE-2024-24974, CVE-2024-27459, CVE-2024-27903, CVE-2024-28882
- Vulnerabilities: Integer Overflow, Unprotected Alternate Channel, Improper Communication Channel Restriction
- Impact: Successful exploitation enables remote code execution or privilege escalation.
11.Siemens SIMATIC IPC Family, ITP1000, and Field PGs
- Alert Code: ICSA-25-072-11
- CVEs: CVE-2024-56181, CVE-2024-56182
- Vulnerabilities: Protection Mechanism Failure
- Impact: An attacker could alter the secure boot configuration or disable BIOS passwords.
12.Sungrow iSolarCloud Android App and WiNet Firmware
- Alert Code: ICSA-25-072-12
- Details: Release of this advisory addresses security issues with Sungrow’s solar management systems, emphasizing the need for updates to prevent unauthorized access.
13.Philips Intellispace Cardiovascular (ISCV)
- Alert Code: ICSMA-25-072-01
- CVEs: CVE-2025-2229, CVE-2025-2230
- Vulnerabilities: Improper Authentication, Use of Weak Credentials
- Impact: Successful exploitation could allow replay attacks to access patient records.
CISA’s issuance of these advisories underscores the urgency of addressing vulnerabilities in Industrial Control Systems.
Users must remain vigilant and implement recommended mitigations to safeguard these critical systems from exploitation.
As technology evolves, so do the challenges in maintaining security. Staying informed and proactive is key to preventing adverse impacts on industrial operations.
To expand this article, you can discuss industry-specific security challenges, current best practices for securing ICS environments, and future trends in cybersecurity for industrial systems.
Additionally, highlighting real-world examples of successful mitigations or past incidents can enhance the article’s relevance and impact.ct.
Are you from SOC/DFIR Teams? – Analyse Malware Incidents & get live Access with ANY.RUN -> Start Now for Free.