Europe’s datacentres will more than double electricity demand over the next decade, from about 96TWh (terawatt-hours) in 2024 to around 236TWh by 2035. Meanwhile, artificial intelligence (AI) rack power draw is set to climb steeply, from around 20kW (kilowatts) now to as much as 1MW (megawatt) apiece.
Bring those two trends together and we find the industry – datacentres and their customers – beginning to measure in metrics such as tokens per watt, time to token and cost per token.
That’s according to executives at Schneider Electric’s datacentre event in Conselve, Italy, this week (pictured above), where speakers cited power delivery as key to the AI build-out. The constraint on AI infrastructure, they argued, has moved to electricity – and to how fast it can be delivered.
“We used to talk about a large datacentre if it reached 30MW,” said Damien Dhellemmes, senior vice-president of Schneider Electric’s secure power and datacentre business in Europe. “When you looked at 50MW, it was a big animal in the traditional datacentre world. Now, with AI datacentres – gigafactories – we’re talking hundreds of megawatts and gigawatt campuses.”
Dhellemmes framed the shift around three pressures: time to power, rack density and heat. “We used to talk about 20kW. Now, we’re talking hundreds of kilowatts. Eventually, in one rack you will have up to 1MW,” he said.
Time to power has become the organising principle, said Dhellemmes. “Time to power means time to token, which means time to money. Let’s be straightforward. It is the number one priority and challenge of AI factories,” he said.
From that has come a new set of yardsticks. Andrew Bradner, who leads Schneider’s cooling business, said the industry now talks in a language of its own. “Now we use things like tokens per watt, time to token and cost per token. These measurements talk about how you can be efficient and profitable when you build AI products,” he said.
Tokens per watt measures how much AI work is produced for the energy consumed, while cost per token measures how efficiently that energy converts into usable output.
The engineering response to these metrics is arriving in several forms.
Modular build is one, with Schneider having launched a prefabricated datacentre range called RapidScale while developing an 800V DC “sidecar” to carry power down to the rack.
Grid flexibility is another. Dhellemmes pointed to DCFLEX, an initiative led by the US Electric Power Research Institute, which Schneider joined with more than 40 companies to work out how datacentres can balance supply and demand by, for example, running heavy AI workloads overnight, or returning stored energy from batteries and uninterruptible power supplies to the grid.
Then there is procurement. Silvia Alchini, who leads Schneider’s secure power business in Italy, argued that long-term power purchase agreements (PPAs) give operators visibility and a route to new renewables.
“The power purchase agreement, for example, is a long-term agreement in which a company can commit to purchasing renewable energy under defined economic conditions,” she said.
Schneider pointed to a French deal that saw Equinix agree 20-year PPAs for more than 300GWh (gigawatt-hours) a year across wind farms in Nouvelle-Aquitaine, Hauts-de-France and Pays de la Loire, and allocated to 11 French datacentres.
Which leaves the question of where AI actually gets built. For UK IT leaders, power price, not just time to power, influences the map. Behind-the-meter renewables and PPAs are available levers, but situating generation behind the meter runs into planning and community opposition in the UK.
That makes the tokens-per-watt and cost-per-token discipline the thing that separates viable builds from the rest. In a market where power is expensive and slow to connect, projects that survive will be the ones that wring the most AI work from every watt.
Datacentre cooling glossary
PUE (power usage effectiveness): Total facility energy divided by the energy the IT equipment uses. A PUE of 1.0 means every watt reaches the servers; 1.2 means 20% extra goes on cooling, power delivery and losses.
WUE (water usage effectiveness): Water consumed per unit of IT energy, usually litres per kilowatt-hour. It captures water use, not the carbon intensity of the grid.
Cooling: Removing the heat that IT equipment produces so chips stay inside their operating range. Air or liquid carries the heat from the servers to the heat rejection step.
Heat rejection: Where the captured heat leaves the building – to outside air through a chiller or dry cooler, or to water.
CDU (coolant distribution unit): The pump-and-heat-exchanger unit in liquid cooling. It circulates coolant to the cold plates on the chips and separates the server (technology) loop from the building (facility) loop.
Chiller: The machine that removes heat from the water loop. Newer units combine refrigerant-based cooling (a compressor circuit) with water-coil free cooling, so they run the compressor only when the outside air is too warm and switch to water cooling when it is cool enough.